![abb power grids abb power grids](https://powertechresearch.com/wp-content/uploads/2018/11/ABB_Aquisition-1080x675.jpg)
Abb power grids update#
Hitachi ABB Power Grids recommends users apply update Version 1.2 FP2 HF6 (Build Nr. Hitachi ABB Power Grids reported this vulnerability to CISA. COMPANY HEADQUARTERS LOCATION: Switzerland.CRITICAL INFRASTRUCTURE SECTORS: Energy.A CVSS v3 base score of 6.3 has been calculated the CVSS vector string is ( AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L). A local operating system user can modify backup files, which may allow an attacker to overwrite system configuration files and gain privileges.ĬVE-2021-35526 has been assigned to this vulnerability. The application does not encrypt backup files.
![abb power grids abb power grids](https://static.seekingalpha.com/uploads/2019/4/22/48060775-1555946794080111_origin.png)
2.257)ģ.2 VULNERABILITY OVERVIEW 3.2.1 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312 SDM600: All versions prior to 1.2 FP2 HF6 (Build Nr.The following versions of System Data Manager are affected: Successful exploitation of this vulnerability could allow an attacker access to sensitive information. Vulnerability: Cleartext Storage of Sensitive Information.